Spares For Eaf

GRAPHITE ELECTRODE FOR EAF

Electrode length and to allow deviations

CARBON ADDITIVE

The high quality anthracite and Graphite Scraps are characteristic of low ash and low sulfur. Carbon additive is used to improve the Carbon content in steel-melting and Ductile iron foundry.

Typical Specifications:

  Gas Calcined Anthracite Electriced Calcined Anthracite Graphite Scraps
F.C 90-92% 95% 99.5%min
S 3%max 0.3%max 0.01%min
Ash 8.0%max 4.0%max 3%max
V.M 1.5%max 1.0%max 0.6% max
Moisture 0.50%max 0.50%max 1% max
Size 1-10mm, 1-5mm, 5-20mm, 10-30mm, 15-40mm
Packing 25kg bags into 1000kg PVC bag, (UV resistance)

WATER COOLED CABLE

Water cooled cable is one kind of special cable used for heating equipment with high current, which is full of water in its inner side. Water cooled cable is made of three parts: electrode, conducting wire and outer hose. Advantage: excellent tightness, pressure resistance and water proofness
Main Parameter

Type Cross-Sectional Area( mm2) GMR Resistance at 70℃ μΩ/m Min. Bend radius(mm) Economic Cross-Sectional area A (mm2)
DC AC50Hz
WCC120 120 -- -- -- 140 600±20%
WCC185 185 -- -- -- 170 925±20%
WCC300 300 -- -- -- 200 1500±20%
WCC400 400 -- -- -- 220 2000±20%
WCC500 500 -- -- -- 220 2500±20%
WCCB1200 1200 20 17.7 18.6 350 4500±20%
WCCB1600 1600 25 13.3 14 400 6000±20%
WCCB2000 2000 29 10.6 11.1 145 7500±20%
WCCB2400 2400 34 8.86 9.3 430 9000±20%
WCCB2800 2800 35 7.6 8 480 10500±20%
WCCB3200 3200 44 6.6 6.9 525 12000±20%
WCCB3600 3600 50 5.9 6.2 580 13500±20%
WCCB4000 4000 56 5.3 5.6 650 15000±20%
WCCB4400 4400 61 4.8 5 660 16500±20%
WCCB4800 4800 65 4.4 4.6 700 18000±20%
WCCB5200 5200 65 4.1 4.3 750 19500±20%
WCCB6000 6000 70 3.5 3.7 900 22500±20%

ELECTRIC CONDUCTIVE ARM

New type electric conductive arm combines function of conduction and electrode grasp with copper-steel complex structure and circular cooling waterway, which forms science and reasonable collocation in electric & structure aspects.

EAF Capacity(t) Transformer Capacity(KVA) Electrode Diameter(mm) Dimension a X b (mm) Loosen Cylinder Pressure(MPa) Cooling Water Consumption (mm3/h)
1.5 1,000-1,250 200 250 x 180 0.4 3
3 2,200-2,500 -250 300 x 200 4
5 2,800-3,200 300 360 x 210 6
10 4,000-5,500 350 420 x 260
15 6,300-8,000 350/400 480 x 340 4 8
20 9,000-13,000 400
30 15,000-20,000 450 500 x 380 10
50 25,000-31,500 500 650 x 450 6 18
75 40,000-50,000 550
100 63,000-80,000 600 800 x 550 25

● Cooling water of arm : treated by high-frequent electric field;
● Double insulation structure: high temperature-resistant coating and insulation plates;
● Electrode clamp: conducts with graphite tile and lined with ceramic tile;
● Pulling rod: series with insulation coupler;
● Conduction block: new material of anti-oxidization

 

网站合作:济南上门按摩
Phone:+86-10-6528 9916
Fax:+86-10-8511 3977
Copyright (c) 2009 MEPC Corporation.All Rights Reserved 京ICP备05011865号